FRP & GFRP Doors
Glass-reinforced polyester doors for environments where steel and timber degrade — water and wastewater plants, desalination and chemical facilities, swimming pool halls, coastal buildings and food processing areas. Supplied as fire-rated leaves with a tested rating up to 90 minutes and as standard non-rated leaves, in a moulded shell that will not rot, rust or delaminate in continuous wet service.
The door leaf is compression-moulded from a chemical-resistant isophthalic / neopentyl-glycol polyester resin reinforced with continuous-strand and woven glass roving, 44 mm or 50 mm nominal thickness, laminated to a pultruded GFRP stile-and-rail subframe with a phenolic-impregnated kraft honeycomb or closed-cell isocyanurate core. Typical laminate properties per ASTM D638, D695 and D790 reach tensile and compressive strengths of 270-380 MPa and a flexural modulus of 7-15 GPa, with Barcol hardness 70-80 and water absorption below 1 % to ASTM D570. Reinforcement-to-resin ratio is held between 65:35 and 75:25 by weight.
Assemblies use fire-retardant resin meeting ASTM E84 / UL 723 Class A flame spread and are certified for 20-90 minutes under BS EN 1634-1, UL 10C or NFPA 252. Thermal transmittance is 0.85-1.4 W/m2K to ASTM C1363 / EN ISO 12567-1 and acoustic performance reaches STC 28-36 to ASTM E90. Structural ratings reach design pressure DP 50-60 under ASTM E330 with zero water penetration at 300-450 Pa to ASTM E331. A 0.60-0.75 mm UV-stabilised marine gelcoat, verified by 1000 h ASTM B117 salt spray, withstands GCC coastal chloride exposure.
- ASTM D638 / ASTM D695 / ASTM D790 — Tensile, compressive and flexural strength and flexural modulus test methods for the rigid GFRP laminate used in door faces and pultruded stile-and-rail profiles.
- ASTM E84 / UL 723 — Surface burning characteristics of the door and frame materials; fire-retardant resin systems are required to reach Class A / Class I flame spread index of 25 or less with smoke index below 450.
- BS EN 1634-1 / UL 10C / NFPA 252 — Fire resistance testing of door assemblies, supporting 20-, 45-, 60- and 90-minute positive-pressure ratings for labelled and non-labelled openings.
- ASTM E330 / AAMA 501.1 — Structural performance of the complete door assembly under uniform static air pressure difference, expressed as a design pressure rating of DP 50 to DP 60 or higher.
- ASTM E331 / ASTM E547 — Water penetration resistance of exterior doors under static and cyclic pressure differential, tested to 300-450 Pa with zero leakage permitted.
- ASTM E90 / ASTM E413 — Laboratory measurement of airborne sound transmission loss, giving a Sound Transmission Class of STC 28 to STC 36 for acoustic and plant-room door openings.
Fire performance is stated only for the tested fire-rated build-up. Where the project cites a national code or an owner specification, the leaf is submitted against that requirement with the corresponding test evidence.
- Hospitality & leisure — exterior entrances at coastal hotels and resorts.
- Desalination & pump stations — plant building doorways exposed to chloride-laden coastal air.
- Water & wastewater — treatment plant doorways in continuously wet and chemical-dosed areas.
- Chemical & petrochemical — process area doorways needing corrosion-resistant, fire-rated leaves.
- Healthcare & laboratories — hospital, clinic and laboratory clean-zone doorways with washdown hygiene duties.
- Education & accommodation — school, university and staff accommodation block entrances.
- Food & cold storage — processing and cold storage plant doorways subject to frequent washdown.
- Ports & marine — port, marina and offshore support building entrances.
- Utilities & telecom — substation and telecom shelter doors where non-conductive leaves are required.
- ISO 9001 quality management system certificate of the manufacturing facility
- ISO 14001 environmental management system certificate
- Third-party fire resistance test report and listing label (20/45/60/90 minute ratings)
- Reaction-to-fire classification report to EN 13501-1
- Accelerated weathering and salt-spray test reports (ASTM B117, ASTM G154, ASTM D2247)
- Manufacturer's material declaration, Environmental Product Declaration (EPD) and 10-year warranty statement
- Leaves, frames, vision panels, louvres and hardware prepared to the door schedule.
- Matching GFRP, stainless steel 316L or galvanized frames, with stainless hardware for wet duty.
- Export packing with face protection, FOB / CFR / CIF to Gulf ports.
Supplied to projects across the Gulf, North and Sub-Saharan Africa, South-East Asia and Australia. Middle East supplies are subject to project-specific approval by the owner, engineer or consultant; PROTEKTA prepares and supports the submittal package for that approval.
FRP & GFRP Doors — Buyer Questions
What fire rating do GFRP doors carry?
Fire-rated leaves are supplied with a tested rating up to 90 minutes, stated for the complete assembly including core, seals and glazing. Non-rated leaves are supplied for corrosion duty and carry no fire performance claim. Supplied for projects across the GCC — Saudi Arabia, UAE, Qatar, Kuwait, Oman and Bahrain — and to Iraq, Algeria, Morocco, Nigeria, Ethiopia, Tanzania, Malaysia, Thailand, Singapore, Indonesia, Brunei and Australia, with compliance documentation prepared for consultant, contractor and authority submittal.
Why specify GFRP instead of steel or timber?
GFRP does not rust, rot or delaminate in continuous wet, chlorinated or chemically aggressive service, and needs no repainting cycle. It is typically specified for water, wastewater, desalination, pool and food processing buildings where coated steel fails early. Also specified and procured as GRP Door and Fibreglass Door; full specification ranges, material grades and datasheets are issued for tender, submittal and procurement use.
What sizes and configurations are available?
Standard leaves up to 1200 × 2400 mm, thickness 40–45 mm, in single, double and oversize configurations with matching frames. Vision panels, louvres and hardware preparations are handled in the submittal. OEM, private-label and bespoke manufacture is supported for contractors, distributors and EPC packages.
What is submitted for approval?
Door schedule, manufacturer’s data sheets, fire test report to the stated rating, reaction to fire classification to EN 13501-1 and laminate test data to ASTM D2583 and D790. Export packing, third-party inspection and consolidated shipment to Gulf ports/global ports are arranged with the order.