Fire-Rated Metal Doors & Frames
Fire-rated hollow metal doors and frames for compartmentation in commercial, healthcare, transport and industrial buildings. Supplied as complete doorsets — leaf, frame, hardware preparations, glazing and intumescent seals — with fire ratings of 60, 90 and 120 minutes under the listed assembly, and acoustic or non-rated variants where the schedule requires a matched appearance across a floor plate.
Manufactured range covers fire-rated hollow metal doors, stainless steel fire doors, glazed stainless fire doors, fire roller shutters and fire windows, plus flush doors and special doors including airtight, radiation-shielding, blast-resistant and explosion-venting types. Flexible sheet-metal lines process steel, aluminium, stainless and coated sheet, with an automatic powder-coating line able to coat large panels.
Fire resistance is verified by third-party laboratories, with documented ratings running from 20 minutes to 180 minutes for hollow metal doors, and to EI120 and E120 for CE-marked assemblies. Glazed assemblies use fire-resisting glass with tested bead and framing details. Additional testing covers air permeability, water tightness, wind-load resistance, sound insulation and smoke leakage, supported by a large-format fire test furnace.
- EN 1634-1 / BS 476-22 — fire resistance tests for door and shutter assemblies.
- EN 13501-2 — fire classification of construction products using fire resistance test data.
- EN 14351-1 / EN 16034 — product standard and CE marking for fire-resisting doorsets.
- ANSI/UL 10B / 10C — installation of fire doors and positive pressure fire tests of door assemblies.
- UL 1784 / EN 1634-3 — air leakage and smoke control testing of door assemblies.
- EN ISO 10140-2 / ASTM E90 — laboratory measurement of airborne sound insulation.
- CAN/ULC S104 — standard method for fire tests of door assemblies, where the project is in Canada.
Acoustic and smoke control performance is stated to the tested assembly — sound reduction to EN ISO 10140-2, smoke leakage to EN 1634-3 or UL 1784 where the schedule calls for it.
- Airports & transport hubs — fire-rated doorsets and shutters for terminals and back-of-house areas.
- Hospitals & healthcare — fire doors with documented acoustic and smoke performance.
- Hotels & commercial towers — fire-rated hollow metal doors, glazed doors and corridor smoke screens.
- Power & nuclear facilities — certified steel doorsets for power stations and nuclear plants.
- Industrial & marine plants — heavy-duty, blast-resistant and explosion-venting doors and shutters.
- Data centres — fire-rated doorsets for server halls, risers and plant rooms.
- UL listing and Intertek or equivalent third-party certification from 20 to 180 minutes.
- CE certification covering air tightness, water tightness, wind load resistance, sound insulation and smoke leakage.
- Independent laboratory fire test reports to the project rating, with the tested configuration stated.
- Material certificates to EN 10204 3.1 for sheet, frame and hardware.
- Per shipment: certificate of conformity, packing list, listing schedule and installation instructions.
- Doorsets scheduled by opening — leaf, frame, finish, hardware preparations and glazing from one submittal.
- Factory-applied finishes: primer, powder coat, or stainless steel cladding to 304 / 316L.
- Export packing with edge protection, FOB / CFR / CIF to Gulf ports/global ports, consolidated with other architectural items.
Supplied to projects across the Gulf, North and Sub-Saharan Africa, South-East Asia and Australia. Middle East supplies are subject to project-specific approval by the owner, engineer or consultant; PROTEKTA prepares and supports the submittal package for that approval.
Fire-Rated Metal Doors & Frames — Buyer Questions
What fire ratings can be supplied?
Doorsets are supplied at 60, 90 and 120 minutes under the listed assembly, tested to ANSI/UL 10C or EN 1634-1 as the project requires. The rating applies to the complete assembly — leaf, frame, glazing, seals and hardware — and is stated against the listing or assessment. Supplied for projects across the GCC — Saudi Arabia, UAE, Qatar, Kuwait, Oman and Bahrain — and to Iraq, Algeria, Morocco, Nigeria, Ethiopia, Tanzania, Malaysia, Thailand, Singapore, Indonesia, Brunei and Australia, with compliance documentation prepared for consultant, contractor and authority submittal.
What is the maximum door size?
Up to H3000 × W3200 mm under the UL listing. Larger openings are handled as assessed extensions or as composite assemblies, subject to the test evidence and the authority having jurisdiction. Also specified and procured as Fire Rated Door, Fire Door and Hollow Metal Door; full specification ranges, material grades and datasheets are issued for tender, submittal and procurement use.
Are acoustic and smoke-rated doors available?
Yes. Acoustic doorsets are supplied with sound reduction to EN ISO 10140-2 and smoke control to EN 1634-3 or UL 1784, so that a single door schedule can cover fire, acoustic and smoke duties with one appearance. OEM, private-label and bespoke manufacture is supported for contractors, distributors and EPC packages.
What is submitted for approval?
Door schedule keyed to room numbers, manufacturer’s data sheets, UL listing or EN test reports, hardware schedule, glazing details, installation instructions and EN 10204 3.1 material certificates. Export packing, third-party inspection and consolidated shipment to Gulf ports/global ports are arranged with the order.