Variable Frequency Drives (VFD)
DivisionDivision 40 Process Interconnections
Section40 90 00 Primary Control Devices
ApplicationsIndustrial & Energy Facilities
PRODUCT

Variable Frequency Drives (VFD)

LV · MV · Four-quadrant · Soft starters — to IEC 61800 and IEEE 519

Power & Industrial Drives IEC 61800 IEEE 519
Overview

Low-voltage and medium-voltage variable frequency drives for pumps, fans, compressors and process drives in power generation, water, steel and general industry. Supplied with soft starters, four-quadrant regenerative units and special power supplies, with speed accuracy to 0.02 per cent and input current distortion held to THDu of 3 per cent or better at the point of common coupling.

Specification

The drive range covers low-voltage general-purpose units from 0.75 kW to 500 kW on 380-440 V supplies and multi-drive engineering units from 90 kW to 5,000 kW on 400-690 V supplies, through medium-voltage converters rated 250 kVA to 15,000 kVA air-cooled and 6,000 kVA to 40,000 kVA water-cooled, with four-quadrant regenerative units from 630 kVA to 30,000 kVA. Reference installations include 3,150 kVA, 9,750 kVA, 10,000 kVA and 14,000 kVA machines at 10 kV and a 22 MW / 10 kV unit, with more than 10,000 units in service.

Medium-voltage converters use a voltage-source H-bridge cascaded multilevel topology with six power cells in series per phase in a three-phase star connection, driven by SPWM output with carrier phase-shifted cascaded control so that output voltage distortion stays at THDu of 3 percent or less. Control is by sensorless or encoder-based vector control with speed accuracy to 0.02 percent, torque vibration suppression, low-voltage pre-charging and self-healing film capacitors. Regenerative units use DSP-generated PWM to hold power factor near unity. Enclosures are rated to IEC 60529.

Standards
  • IEC 61800-2 — General requirements for low-voltage adjustable speed a.c. power drive systems, including rating and performance.
  • IEC 61800-3 — Electromagnetic compatibility requirements and emission and immunity limits for power drive systems.
  • IEC 61800-4 — Rating specifications for a.c. power drive systems above 1000 V and up to 35 kV.
  • IEC 61800-5-1 — Electrical, thermal and energy safety requirements for adjustable speed power drive systems.
  • IEEE 519 — Recommended practice for harmonic control in electrical power systems and supply distortion limits.
  • IEC 60529 — Classification of degrees of protection provided by enclosures, expressed as the IP code.

EMC, harmonic and enclosure ratings are stated per installation. Where the project cites an owner power quality standard or a utility grid code, the drive is configured and tested to that limit.

Applications
  • Power Generation — boiler feed water and circulating water pump drives; induced draught and primary air fan drives.
  • Oil & Gas — pipeline compressor and process pump drives.
  • Metals & Mining — sintering machine exhaust fan and blast furnace blower drives.
  • Cement & Building Materials — kiln induced draught fan and grate cooler fan drives.
  • Water & Wastewater — municipal booster pump and clean water pump drives.
  • Marine & Ports — ship shore-power supply and port hoisting drives.
  • Industrial Manufacturing — wind tunnel and dynamic balancing test bench drives.
  • New Energy — pv plant and battery energy storage power conversion.
Certificates & documentation
  • ISO 9001 quality management system certificate covering design and manufacture
  • IEC 61800 series type test report issued by an accredited laboratory
  • Declaration of conformity to the Low Voltage and EMC directives for the European market
  • Supply harmonic and EMC compliance test report to IEC 61800-3 and IEEE 519
  • Marine classification society type-approval certificate for shore-power converters
  • ISO 14001 environmental management system certificate
Supply capability
  • Drive, braking, filtering and enclosure supplied as one configured package.
  • Harmonic study and motor compatibility review — cable length, bearing currents, insulation stress.
  • Export packing, FOB / CFR / CIF to Gulf ports/global ports, with commissioning and training support available.
Approval

Supplied to projects across the Gulf, North and Sub-Saharan Africa, South-East Asia and Australia. Middle East supplies are subject to project-specific approval by the owner, engineer or consultant; PROTEKTA prepares and supports the submittal package for that approval.

FREQUENT QUESTIONS

Variable Frequency Drives (VFD) — Buyer Questions

What power range is covered?

Low-voltage drives from 0.75 kW to 500 kW and medium-voltage drives from 90 kW to 5000 kW, on input supplies of AC 380–440 V and AC 400–690 V depending on series. Four-quadrant units and soft starters are included in the range. Supplied for projects across the GCC — Saudi Arabia, UAE, Qatar, Kuwait, Oman and Bahrain — and to Iraq, Algeria, Morocco, Nigeria, Ethiopia, Tanzania, Malaysia, Thailand, Singapore, Indonesia, Brunei and Australia, with compliance documentation prepared for consultant, contractor and authority submittal.

How are harmonics handled?

Input current distortion is held to THDu of 3 per cent or better, using line reactors, DC chokes, active front ends or multi-pulse arrangements as needed. A harmonic assessment to IEEE 519 at the point of common coupling is provided per project. Also specified and procured as Variable Speed Drive and Inverter Drive; full specification ranges, material grades and datasheets are issued for tender, submittal and procurement use.

Can drives be supplied for data centre cooling duty?

Yes. Drives are supplied for chilled water pumps, cooling tower fans and CRAH units, where part-load efficiency and harmonic limits at the point of common coupling govern the selection. OEM, private-label and bespoke manufacture is supported for contractors, distributors and EPC packages.

What documentation is provided and delivery terms?

Type test and EMC reports to IEC 61800, harmonic assessment to IEEE 519, CE declaration or UL listing, plus a commissioning report and parameter backup per unit. Export packing, third-party inspection and consolidated shipment to Gulf ports/global ports are arranged with the order.